Technical parameters
Øname: toilet pump Title: Septic pump
Øambient temperature: -25-50 Degree ambient temperature: 25-50 Degree
ØCOLOR: Black: Black
ØDRIVER Type: DC current type of drive: DC
ØFlow flow speed, QMAX: 50 ± 15% l/min flow rate, QMax: 50 ± 15% l/min
ØHEAD Speed . hmax: 8.0 ± 5% m Maximum pressure: 8.0 ± 5% m
Øhousing Material: ABS case material: ABS
Øinput power: 54 ± 1 W input power: 54 ± 1 W
Øinsulation class: F (155 Degree) Isolating class: F (155 Degree)
ØIP degree: IP67 IP degree: IP67
Øleakproofness: Greater than or Equal to 0.4mpa Seal: Greater that or Equal to 0.4 MPA
Ølifetime: 20,000 service life: 20,000h
Ølique temperature: 0-50 Degree fluid temperature:0-50 Degree
Ømodel: re20-8 Model: re20-8}}
Ønoise: Less than or Equal To 40 dBA / 1 meter noise: Less than Or Equal To 40 DBA / 1 meter
ØOPREATISTING voltage: 8-20 to operating voltage: 8 ~ 20V
ØPUMP Building: PA {{0}
ØRated current: 4.5 ± 10% A rated current: 4.5 ± 10% A
ØRated voltage: DC 12 (V) REAL voltage: DC 12 (V)
Øweight: 0.455kg weight: 0.455kg
The use of products
1 gas water heater, an electric water heater
2 sun water heater, water heating mattress
3 intellectual toilet, intellectual bath, dishwasher
4node energy vehicles, water cycle of electric vehicles
Peculiarities
1 waterproof and sealed, can be used in a humid environment and amphibians .
2 thousands, energy -saving, environmentally friendly
3sos for septicade stable performance, safety and reliability
Our advantages
1. Constant power: when the input voltage exceeds 13 ± 1 V, the operating current of the pump for the septic tank is automatically adjusted, and the high expense and maximum pressure remain almost unchanged .}
2. Coal protection: when there is no liquid in the pump, the pump goes into idle mode for 5 C and the speed decreases; When there is a liquid, the pump returns to normal operation within 5 C . if the pump is idling for 120 ± 20 s, it automatically stops . The septic tank should be turned off and restart to resume normal operation .}}}}}
3. protection against overvoltage: the defense protection value is 20 ± 1 in . when the input voltage exceeds the value of the protection, the pump stops working within 2 seconds; когда входное напряжение меньше значения защиты, насос восстанавливается в течение 2 секунд. Защита от пониженного напряжения 8±1 В. Когда входное напряжение меньше значения защиты, насос прекращает работу в течение 2 секунд; When the input voltage is greater than the protection value, the pump is restored within 2 seconds .
4. Clocketing protection: if the rotor is jammed, it will automatically stop working, restart after about 5 s, will scroll 5 times, and then stop .}}}}}}}}
Hot Tags: Septic pump pump, China pump for septic tank manufacturers, suppliers, factory







